English
BakerTop
™
ChefTop
™
Gas Setup
The gas type in the gas pipe network must be checked by a qualified technician that, if necessary, replaces
the nozzle, adjusts the primary air and sets the type of gas on the oven control panel and apply the label.
Nozzle replacement and primary air adjustment
Using the table in the attached technical data sheet, replace the main injector and adjust the primary air using
the corresponding bushing. This procedure should only be carried out once the gas valve upstream of the
oven has been shut off and the power supply disconnected. Make sure that the diameter measurement of the
injector to be replaced is stamped on it, in hundredths of a millimetre (1/100 mm). The injector is located at
the rear, on the bottom left-hand side. To replace the injector and adjust the primary air, proceed as follows
(see illustration below):
• Loosen screw A.
• Adjust bushing B in accordance with the information provided in the
attached table.
• Unscrew and remove injector C using a 13 mm spanner.
• Install the injector most suited to the type of gas supplied (see relevant
technical table).
• Position bushing B at the correct distance H (see relevant technical table).
• Re-tighten screw A.
There are 2 types of nozzle:
- one suitable for G20, G25 and G25.1 gas
- one suitable for G30 and G31 gas
OVEN GAS NOZZLE CODE
NOZZLE DIAMETER
[1/100 mm]
PRIMARY AIR
L [mm]
INSTALLATION
XBC 615 G
G20, G25, G25.1 BR1275A0 345
All open
L=39 mm
In the appliance
G30,G31 BR1055A0 225 Installed
XBC 815 G
G20, G25, G25.1 UG1001A0 375
All open
L=39 mm
In the appliance
G30,G31 BR1250A0 245 Installed
XVC 315 G
G20, G25, G25.1 BR1020A0 280
All open
L=39 mm
In the appliance
G30,G31 BR1085A0 185 Installed
XVC 515 G
G20, G25, G25.1 BR1270A0 335
All open
L=39 mm
In the appliance
G30,G31 BR1150A0 220 Installed
XVC 715 G
G20, G25, G25.1 BR1280A0 360
All open
L=39 mm
In the appliance
G30,G31 BR1180A0 230 Installed
XVC 1215 G
G20, G25, G25.1 BR1275A0 345
All open
L=39 mm
In the appliance
G30,G31 BR1055A0 225 Installed
XVC 2015 G
G20, G25, G25.1 UG1001A0 375
All open
L=39 mm
In the appliance
G30,G31 BR1250A0 245 Installed
XVC915G - XVC1015G
XBC915G - XBC1015G
G20, G25, G25.1 BR1245A0 355 L=39 mm In the appliance
G30,G31 BR1055A0 225
All open
L=39 mm
Installed
XVC3215G - XVC4015G
G20, G25, G25.1 BR1245A0 355 L=39 mm In the appliance
G30,G31 BR1055A0 225
All open
L=39 mm
Installed
Gas connections
49