Power cabling vacon • 41
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
4
Tightening torques of cable glands:
UL installation:
Figure 27.Cable entry plate, MM4 UL installation.
Table 19. Tightening torque and dimension of cable glands.
Enclosure
size
Gland screw
type [metric]
Tightening torque [Nm]/[lb-in.]
[Nm] lb-in.
MM4
M16 1.0 8.9
M25 4.0 35.5
MM5
M16 1.0 8.9
M25 4.0 35.5
M32 7.0 62.1
MM6
M16 1.0 8.9
M25 4.0 35.5
M40 10.0 88.7
6
To connect NPT pipes to VACON
®
100 X, use the optional metal cable entry
plate (included in -R02 option) to meet UL installation rules.
One metal conduit plate with accessories (screws and gasket) is delivered in a
separate bag together with the drive. See the following figures for more
details.