5. In the NET settings, depending on the data type:
Press the arrow to open the list and select from the list of options.
Press the data field to open the typing pad. When finished, press OK.
Connection type
UDP, TCP server, or TCP client.
Local host address
IP address of the display device.
Local port
(UDP and TCP server mode only) Local port number.
Remote host address
(UDP and TCP client mode only) IP address of the target communication device
or sensor.
If you want to accept a connection from any IP address in the UDP mode, you can
set the remote address to 0.0.0.0 and the remote port number to 0. However,
then sensor message polling cannot be used.
Remote port
(UDP and TCP client mode only) Port number of the communication device or
sensor.
Accept mode
(TCP server mode only) Select the needed mode: Multiplex, First, or Last.
TCP open timeout (s)
(TCP server mode only) Type the time that the server waits before triggering an
alarm about not being able to establish connection to the client. 0 = no timeout
(no alarms).