EasyManua.ls Logo

Vaisala AviMet WID511 - COM Port Configuration and Data Viewing

Vaisala AviMet WID511
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(Wind sensor only) Select True north or Magnetic north depending on
the actual alignment of the wind sensor. See also Configuring station settings
(page 79).
Sensor ID
Type the ID of the sensor, when applicable.
In the poll mode, the ID must be defined and must match the ID in the sensor.
Otherwise the poll command that is sent from the display is not correct.
The display uses asterisk (*) as wildcard character. It means that any character is
accepted when receiving sensor ID in the message.
If several sensors are using one communication channel in the autosend mode,
you have to create message IDs for each of them.
If several sensors are using dierent communication interfaces in the autosend
mode, it is a good idea to create the IDs to check the functioning of the
interfaces.
Sensor di to ref. alt. (m)
(Pressure sensor only) The dierence between sensor altitude and reference
altitude. When the sensor is installed below reference altitude, the value is
negative.
7. To save the changes, press Apply.
The changes are valid only after pressing Apply.
More information
Selecting messages in use (page 67)
Wind message formats (page 90)
7.16
Configuring COM port settings
You can change the current or default COM port settings for serial connection.
1. Enter Maintenance mode.
2. On the Advanced settings page, press COM.
Chapter 7 – Advanced settings in Maintenance mode
71

Table of Contents

Related product manuals