Name Description
\wd
Wind direction, average
\wp
Wind speed, maximum
\wm
Wind speed, minimum
\Ts
Sonic temperature
\vh
Heater voltage
\vi
Supply voltage
\ta
Transducer temperature
\er
Status code. The code is a decimal number. Each bit corresponds to a status flag.
\se
Checksum calculation end point, not shown in the message
\sp
Print checksum (to verify message integrity)
WMT700 data message 24 does not include a device ID and therefore does not support
polling.
Example
$03.45,76.03,03.58,03.37,21.97,23.8,23.6,23.8,0,0B<cr><lf>
Wind speed, average
3.45 m/s
Wind direction, average 76.03°
Wind speed, maximum 3.58 m/s
Wind speed, minimum 3.37 m/s
Sonic temperature 21.97 °C
Heater voltage 23.8 V
Supply voltage 23.6 V
Transducer temperature 23.8 °C
Status code 0
Checksum D4
A.1.3 WAT11 message
The fixed-length WAT11 message can be used to receive wind data.
<STX><ID><spd><dir>
WID511 User Guide M211109EN-L