EasyManua.ls Logo

Vaisala GMP252 - 11 Technical Data; GMP252 Specifications; Table 47 Measurement Performance

Vaisala GMP252
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Technical Data
11.1 GMP252 Specifications
Table 47 Measurement Performance
Property Description/Value
Measurement range 0 ... 10 000 ppmCO
2
(up to 30 000 ppmCO
2
with reduced accuracy)
Accuracy at 25 °C and 1013 hPa (incl. Repeatability and Non-Linearity)
0 ... 3000 ppmCO
2
±40 ppmCO
2
3000 ... 10 000 ppmCO
2
±2 % of reading
Up to 30 000 ppmCO
2
±3.5 % of reading
Calibration Uncertainty
at 2000 ppmCO
2
±38 ppmCO
2
at 10 000 ppmCO
2
±105 ppmCO
2
Long-Term Stability
0 ... 3000 ppmCO
2
±60 ppmCO
2
/year
3000 ... 6000 ppmCO
2
±150 ppmCO
2
/year
6000 ... 10 000 ppmCO
2
±300 ppmCO
2
/year
Temperature Dependence 0 ... 10 000 ppmCO
2
with compensation, -10 ... +50 °C ±0.05 % of reading/°C
with compensation, -40 ... +60 °C < ±0.1 % of reading/°C
without temperature compensation at 2000 ppmCO
2
(typical)
-0.5 % of reading/°C
Pressure Dependence
with compensation at
0 ... 10 000 ppmCO
2
, 500 ... 1100 hPa
±0.015 % of reading/hPa
without compensation (typical) +0.15 % of reading/hPa
Humidity Dependence
with compensation,
0 ... 10 000 ppmCO
2
, 0 ... 100 %RH
±0.7 % of reading (at +25 °C (+77 °F))
without compensation (typical) +0.05 % of reading/%RH
O
2
Dependence
Chapter 11 – Technical Data
103

Table of Contents

Related product manuals