5. Select the button next to Product Type and Product Name, select up to 3 products to
be examined by the WARN product.
Products must have the same maximum product range per the respective
Product Configuration menus.
Products must have the same resolution per the respective Product
Configuration menus.
Products must be of a supported data type: dBT, dBZ, dBZc, Height, Kdp,
LDRH, LDRV, R, Rain, RhoH, RhoV, RhoHV, Shear, SQI, Time, VIL, Width,
and ZDR.
Errors are reported at run time in the Radar Status menu.
a. Select the product type.
The Product Name information is filled in automatically. You can also edit the name.
b. Select the product name.
The list of product names shows products currently in your system. If the product
you want does not show, run your system until it does show.
Alternatively, chose a dierent product of the desired type and override the
product name.
c. For each product, use Time values to use products from dierent tasks or dierent
runs of the same task.
Use the plus and minus buttons to increase or decrease the hours, minutes, or
seconds or type a time value in the window.
This field applies only when there is more than one criterion. For example, if the
second criterion has a time of 00:10:00, when the first product becomes available,
the scheduling algorithm searches back in time as far as 10 minutes to find a version
of the second product.
You must know your task schedule. If you use products based on dierent tasks, you
must set the Time field to some nonzero number or the product does not run. In
general, if all of your product criteria are based on the same task, set all the times to
00:00:00 so that only data from the same run are used.
d. For each product, enter the warning threshold in Threshold.
The WARN product considers only those values that meet or exceed the threshold.
The units of measure depend on the selected product. For example
TOPS thresholds are specified in km
VIL thresholds are specified in mm.
Check the appropriate
Product Configuration menu if you are uncertain about
the units of measure.