EasyManua.ls Logo

Vaisala IRIS - Configuring SWS Input; Figure 74 SWS Raw Report Example

Vaisala IRIS
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 74 SWS Raw Report Example
5.8.4
Configuring SWS Input
SWS data arrives on an IRIS system through a file transfer and ingest mechanism.
You must configure a source of METAR and/or SYNOP messages to transfer ASCII files to a
known directory on the IRIS Analysis system. IRIS monitors this directory for new files, then
runs an input pipe to convert this data to IRIS's internal SWS format and insert into the IRIS
product directory.
You must configure the SWS input.
1. Make sure you use a recent version of the metar2iris pipe by copying the binary and
config files from config_template directory to config directory.
This pipe parses metar and synop messages.
$ cd /usr/sigmet/config_template
$ cp pipes/metar2iris /usr/sigmet/config/pipes|
$ cp metar* /usr/sigmet/config
Chapter 5 – Configuring and Scheduling Optional IRIS Products
RESTRICTED 199

Table of Contents