1. Setup an IRIS configuration for wind shear, so that when potentially hazardous weather
approaches the terminal area, IRIS can be switched to wind shear monitoring mode by
loading the configuration into the Radar Status menu.
You can a operate the WARN product in surveillance mode to alert the operator that
the mode should be switched, or the automatic mode switching feature can be used.
For example, the surveillance mode could consist of a 15 elevation volume scan
sequence. The WARN product can be keyed on a severe storm indicator such as VIL. If
VIL exceeds a threshold value typical of severe storms for the area, and this VIL is
within 30 km (18.6 mi) of the terminal, the WARN product can issue an alarm advising
the operator or the automatic mode switch to change to the wind shear detection
mode.
IRIS Product and Display User Guide M211319EN-H
184 RESTRICTED