Right
User
Profile
Type
Default
Description
Isolate Standard*
Manager
Isolating a zone deactivates that zone until such time as the zone is de-isolated. All
zone types on the controller can be isolated.
Use of this feature to deactivate faulty or open zones should be considered carefully;
once a zone is isolated, it is ignored by the system and could be overlooked when
setting the system in the future, compromising the security of the premises.
User Rights - System
Web
Access
Standard*
Manager
User can access panel through web browser.
View Log Standard
Manager
This menu option displays the most recent event on the keypad display. The event
log (see Event Log on page166) details the time and date of each logged event.
Users Manager User can create and edit other users on the panel but with only the same or less rights
than this user.
SMS Standard*
Manager
This feature allows users to set up the SMS messaging service if a modem is
installed on the system.
Set Date Standard
Manager
Use this menu option to program the time and date on the system (see Set Date/Time
on page169).
Ensure the time and date information is accurate; these fields are presented in the
event log when reporting system events.
Change
PIN
Standard
Manager
This menu option allows users to change their user PINs (see Change Engineer Pin
on page167).
Note: To comply with INCERT approvals, the user’s PIN code must contain more
than 4 digits.
View
Video
Standard
Manager
User can view video images via the web browser.
Note: The Web Access right must also be enabled for this function.
Chime Standard
Manager
All zones that have the CHIME attribute set generate a short burst of audible tone on
the keypad buzzer when they are opened (while the system is unset).
This menu option allows for enabling or disabling of the chime feature on all zones.
Engineer Manager This option allows users to grant access to engineer programming.
For Swiss CAT 1 and CAT 2 regional requirements, when Engineer Access is
granted, all areas must be unset otherwise the engineer will be denied access.
Upgrade Manager User can grant manufacturer access to panel to perform firmware upgrade.
User Rights - Control
Outputs Standard
Manager
User can activate/deactivate configured outputs (mapping gates). See Editing an
output on page231.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 201 A6V10276959-d
11.2018