RF FOB
SOS
Select how the SOS buttons on the RF Fob should operate.:
l Disable
l Enable
l Enabled Silent
l User Medic
l User Holdup
l RF Output
WPA Test
Schedule
1
Enter a maximum period (in days) between WPA tests.
Prevent
Setting
Time
Enter a time in minutes after which, if the sensor fails to report, a setting is prevented for an area
where the wireless zone is.
This setting applies to the following intrusion zones only:
l Alarm
l Entry/Exit
l Exit Term
l Panic
l Hold up
l Tamper
l Lock Supervision
l Seismic
l All OK
l Setting Authorisation
l Lock Element
Device Lost
Time
Enter a number of minutes after which the wireless device (sensor or WPA) device is reported as
lost.
1
A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
For CE regulatory compliance, the SPCW120 product is to be fitted to the following products only:
l SPC5330.320-L1
l SPC6330.320-L1
l SPC4320.320-L1
l SPC5320.320-L1
l SPC5350.320-L1
l SPC6350.320-L1
17.10 Configuration
This section covers:
17.10.1 Configuring controller inputs and outputs 229
17.10.2 X-BUS 238
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 228 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPCA210.100 and is the answer not in the manual?

Vanderbilt SPCA210.100 Specifications

General IconGeneral
BrandVanderbilt
ModelSPCA210.100
CategoryPower Supply
LanguageEnglish

Related product manuals