Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½”), DeviceNet
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
35. Tighten plate screws to block.
36. Loosen the plate screws a quarter turn
counter clockwise so that plate is still
movable at shaft.
37. Press the plate (A) into valve seat.
38. Press the lever by hand to axis (C). Make
sure that lever (B) is engaged at axis (C)
completely. (mechanical close position).
39. Fasten the plate screws with 2.5 Nm
40. If some grease on plate surface or valve
body clean it with lint and dust free cloth
Allen torque wrench
3mm
Cleanroom wipes
Mount
control and actuating unit
to valve unit
41. Assemble valve unit with control and
actuating. Push axis (C) into clamp
coupling