EasyManuals Logo

Vertiv NetSure 8200 Series Installation Manual

Vertiv NetSure 8200 Series
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Vertiv | NetSureâ„¢ 8200 Series -48 VDC Power System Installation Manual (IM582140000) | Rev. A
3
TABLE OF CONTENTS
Admonishments Used in this Document ............................................................ 6
Important Safety Instructions .............................................................................. 7
Safety Admonishments Definitions ...................................................................................................... 7
General Safety ........................................................................................................................................................... 7
Voltages ........................................................................................................................................................................... 7
AC Input Voltages ........................................................................................................................................................ 7
DC Output and Battery Voltages .................................................................................................................. 7
Battery .............................................................................................................................................................................. 8
Personal Protective Equipment (PPE) ............................................................................................. 9
Hazardous Voltage .............................................................................................................................................. 9
Handling Equipment Containing Static Sensitive Components............................. 9
Maintenance and Replacement Procedures .............................................................................. 9
Static Warning ......................................................................................................... 10
Customer Documentation Package .................................................................... 11
Installation Acceptance Checklist ..................................................................... 12
Placing the Bays and Installing Internal/External Busbars ........................ 14
General Requirements .................................................................................................................................... 14
Placing and Securing List 101 and List 111 Power/Distribution Bays
(without PDSC) ...................................................................................................................................................... 14
Placing and Securing List 102 and List 112 Power/Distribution Bays
(with PDSC) ............................................................................................................................................................... 16
Placing and Securing List 103, 104, 105, 113, 114, and 115 Power Only
Bays ................................................................................................................................................................................... 17
Placing and Securing List 116, 117, 118, and 122 Distribution Only Bays ........ 19
Installing Power/Distribution Bay to Power/Distribution Bay Negative
and Positive Busbar Links.......................................................................................................................... 38
Installing Power/Distribution Bay to Power/Distribution Bay Negative
and Positive Busbar Links (Newer Style Bay to an Existing Older
Style Bay) ..................................................................................................................................................................... 41
Connecting Power/Distribution Bay Rectifier Mounting Position AC
Input Connectors to PDSC (Lists 102 and 112 Only) ....................................................... 43
Installing Power/Distribution Bay External Top-Mount Horizontal
Battery Input Busbar Assembly, P/N 554873 (if furnished) ..................................... 44
Installing Optional Power/Distribution Bay Busbar Shield Kit, P/N
528482 (if furnished) ...................................................................................................................................... 53
Installing Power/Distribution Bay External Top-Mount Ground (Load
Return) Busbar Assembly; P/N 514688, 514689, 514690, or 514691 (if
furnished) ................................................................................................................................................................... 54
Installing Power/Distribution Bay Load Return Lug Extension Busbar
Assembly, P/N 514543 (if furnished)............................................................................................... 70
Installing Power/Distribution Bay External Top-Mount Vertical
Battery Input Busbar Assembly, P/N 554874 (if furnished)..................................... 79
Installing Distribution Only Bay External Top-Mount Ground (Load
Return) Busbar Assembly; P/N 528775 (if furnished) .................................................... 88

Table of Contents

Other manuals for Vertiv NetSure 8200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vertiv NetSure 8200 Series and is the answer not in the manual?

Vertiv NetSure 8200 Series Specifications

General IconGeneral
BrandVertiv
ModelNetSure 8200 Series
CategoryPower Supply
LanguageEnglish

Related product manuals