Electrical Troubleshooting Procedures LTC Repair
wc_tx000429gb.fm 118
7.27 Replacing Generator Capacitor(s)
See Graphic: wc_gr002460
Carry out this procedure with the engine shut down.
Removal:
7.27.1 Note the connection points of the #60 (#50 on 50Hz machines) and #0
wires and remove the wires (a) from the capacitor (b).
7.27.2 Remove the jumper wire (c) connecting the two capacitors.
7.27.3 Cut the wire ties (d) and remove the capacitor(s).
Installation:
7.27.4 Insert the capacitors (b) and secure with new wire ties (d).
7.27.5 Attach the #60 (#50 on 50Hz machines) and #0 wires to the
appropriate terminals on the capacitor.
7.27.6 Attach the jumper wire (c).