3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
As dened in the Directive 2014/34/EU (ATEX), the device is suitable for use in potentially
explosive areas.
Device types: IceBreaker piston pump
PROTEC 95-150
PROTEC 72-200
PROTEC 60-240
Tiger 72-300
Manufacturer: Wagner International AG
CH-9450 Altstätten, Switzerland
European Communities
Symbol for explosion protection
Device class II
Category 2 (zone 1)
Ex-atmosphere gas
Explosion protection
Ignition protection for non-electrical devices
Explosion group
Maximum surface temperature < 200 °C; 392 °F (without drying protection
active)
Maximum surface temperature < 135 °C; 275 °F (with drying protection
active)
High safety level
There are special instructions to ensure safe operation.
See the following Chapter "Identication X".
3.2 IDENTIFICATION "X"
The maximum surface temperature corresponds to the permissible product temperature.
This and the permissible ambient temperature can be found in Chapter 5.5.3 and 5.5.6
(Technical data regarding the Jaguar, Tiger and PROTEC pumps).
Safe Handling of WAGNER Spray Devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
knocking or pushing metal against metal is to be avoided;
Do not drop the device or components.
Maximum surface temperature
The maximum surface temperature of the piston pump can be reached if it runs dry.
Ensure that the piston pump is lled with sucient working or ushing agent.
Ensure that the separating agent tank is lled with sucient separating agent.
Ignition temperature of the coating product
Ensure that the ignition temperature of the surrounding gases (pumping product,
cleaning agents) is higher than the maximum permitted surface temperature of the
device.
Ambient temperature
The permissible ambient temperature range is: 5 °C to 50 °C; 41 °F to 122 °F.