8 CLEANING AND MAINTENANCE
8.1 CLEANING
8.1.1 CLEANING PERSONNEL
Cleaning work should be undertaken regularly and carefully by qualied and trained
personnel. They should be informed of specic hazards during their training. The following
hazards may arise during cleaning work:
− Health hazard from inhaling solvent vapors.
− Use of unsuitable cleaning tools and aids.
8.1.2 DECOMMISSIONING AND CLEANING
The device should be cleaned for maintenance purposes, etc. Ensure that no remaining
product dries on and sticks to the device.
Procedure
1. Carry out work interruption Chapter 7.4.
2. Carry out the basic ushing Chapter 7.5.
3. Empty system in a controlled manner Chapter 8.2.4.
4. Service spray gun in accordance to its operating manual.
5. Clean and check the suction system and the suction lter.
6. When using a product lter, check lter insert and lter housing and clean or replace
them. Chapter 8.2.6
7. Clean the outside of the system.
8. Fully assemble the system.
9. Check ll level of the separating agent Chapter 8.2.3.1.
10. Fill the system with ushing agent in accordance with Chapter 8.2.5.
8.1.3 LONGTERM STORAGE
When storing the device for longer periods of time, it is necessary to thoroughly clean it
and protect it from corrosion. Replace the water or solvent in the product pump with a
suitable preservative, ll separating agent cup with separating agent.
Procedure
1. Perform points 1 to 8 in Chapter 8.1.2.
2. Fill the system with preservative in accordance with Chapter 8.2.5.
3. Empty the system in a controlled manner in accordance with Chapter 8.2.4 and seal
the openings.