21
VERSION 01/2020
ORDER NUMBER DOC2340282
IceBreaker 150-300 cm
3
5.5.3 TECHNICAL DATA FOR PROTEC
Description Units
Pump ratio 95:1 72:1 60:1 60:1
Volume ow per double stroke
cm; cc 150 200 240 240
Maximum operating overpressure
MPa
bar
psi
53
530
7687
53
530
7687
48
480
6962
27
270
3916
Maximum possible strokes in operation
/min.
60
Maximum recommended strokes per minute in
continuous operation
/min.
40
Minimum/maximum air inlet pressure
MPa
bar
psi
0.25–0.56
2.5–5.6
36–81
0.25–0.74
2.5–7.4
36–107
0.25–0.80
2.5–8.0
36–116
0.25–0.46
2.5–4.6
36–67
Compressed air quality: free from oil and water
Quality standard 7.5.4 according to ISO 8573.1, 2010
7: Particle concentration 5–10mg/m³
5: Humidity: pressure dew point ≤ 7 °C
4: Oil content ≤ 5mg/m3
Air inlet (inside thread) inch G1"
Minimum of the compressed air supply line mm; Inch 25; 0.98
Air consumption at 0.6 MPa; 6 bar; 87 psi per double
stroke
nl
scf
103.1
3.64
Air motor piston diameter mm; Inch 250; 9.8
Air motor piston stroke mm; Inch 150; 6
Sound pressure level at maximum permissible air pressure* dB(A) 83
Sound pressure level at 0.6 MPa; 6 bar; 87 psi air pressure* dB(A) 80
Sound pressure level at 0.4 MPa; 4 bar; 58 psi air pressure* dB(A) 76
Product inlet (inside thread) mm G1½"
Product output (outside thread) mm M24×1.5
Weight kg; lb 59; 130.1 60; 132.3 60.5; 133.5
Product pH value pH 3.5–9
Maximum product pressure at pump inlet
MPa
bar
psi
2
20
290
Product temperature 5–80; 41–176
Ambient temperature
Construction and
assembly
5–50; 41–122
Storage -20–60; -4–140
Relative humidity % 10–95 (without condensation)
Allowable inclination for operation ± 10
A-rated sound pressure level measured at 1 m distance, LpA1m, according to DIN EN 14462: 2005.
Reference measurements have been made by SUVA (Swiss National Accident Insurance Fund).
No longer available!
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water.

Table of Contents