13.14 Plugs and sockets
13.14.1 Sensor
Sensor input: Optically decoupled
Standard: NPN (switching to GND)
Can be rejumpered to PNP.
Photocell with 4-pole M8 round plug
PIN
Description
Value
Unit
1
Power max. 100 mA
+ 24
V
2
Optionally in/output
+24
V
3
GND
0
V
4
Start pulse
Input standard NPN
The PIN2 can optionally be used as an additional input or output.
This must be programmed customer-specifically.
Input NPN as standard, can be rejumpered to PNP.
Output 24V / 10mA, active high.
CAUTION!
If PIN2 is used as the output it must not be loaded
with more than 10 mA.
E.g. PLC input
Floating contact (normally open) for start pulse with 4-pole M8
round plug
PIN
Description
Value
Unit
3
GND
0
V
4
Start pulse
Input standard: NPN