Weber Markoprint iJET - Table of Faults

Weber Markoprint iJET
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Art. No.: 72801001
Faults
Page 82 of 127
10.2 Table of faults
Disorder
Possible cause
Troubleshooting
Recovered by
Controller
does not start
No power supply
Check power supply
Electrician
No screen
display
No signal from the system
Start the system
Instructed person
Print head
does not
produce a
print image
No start pulse
Check photocell and
connection cable
Electrician
Print parameter incorrect
Check print parameter, adjust
if necessary
Instructed person
Fault in the electronics of the
controller or the print head
Send controller or print head
in for repairs
Manufacturer
Faulty rotary encoder or incorrect
rotary encoder settings
Check rotary encoder and
encoder settings
Instructed person
Pale and
blurred print
image
Distance between print head and
object too large
Reduce distance to 0 - 4…5
mm
Specialist
Low intensity
Raise intensity
Instructed person
Ink cartridge empty
Replace ink cartridge
Instructed person
Closed nozzles
Start spitting and wipe the
nozzle plate off, carefully
Instructed person