Page 54 of 127
8.3 Switching on
1. In standby mode, keep the iLOGIK pressed for approx. three
seconds, or connecting PoE cable to the system unit and the
power pack to the voltage supply.
The controller must conduct a self-test and briefly
indicates the unit version number after the company logo
has passed through the display.
After approx. 10 seconds the status menu-1 appears on
the display.
8.4 Switching off
1. Disconnect the power pack from the voltage supply and the
system unit is switched off, or keep the iLOGIK pressed for
approx. ten seconds.
The controller passes to standby mode.
8.5 User language
It is possible to switch the user language to English, German, or
French. Set the menu language via the software iDesign, web
browser or on the control system.
iDesign
Below: Functions
System settings
Advanced settings
Language, afterwards confirm with the send-button.
Finally complete it by a step up-/downwards in the menu structure
of the iJET.
WEB-Browser:
Below: Settings
Advanced settings
Language, afterwards
confirm with the send-button.
Finally complete it by a step up-/downwards in the menu structure
of the iJET.
Control system iJET:
To set the language on the control system see Chapter 8.27,
page 75.