Art. No.: 72801001
Operation
Page 64 of 127
Parameter
Min.
Max.
Unit
Encoder
50
5000
ppi
Print intensity
50
900
dpi
Printing width
10
900
%
To enter a variable print speed,
To enter a constant print speed,
1. Touch the iLOGIK once in one of the status menus.
The Label submenu is displayed.
2. Call the System submenu by rotating the iLOGIK and select
by pressing.
The System submenu is displayed.
3. Call the Nozzle Clock submenu by rotating the iLOGIK and
select by briefly pressing.
4. Set the value to Intern by rotating the iLOGIK and confirm by
brief pressing.
5. Jump a level by pressing the iLOGIK slightly longer and call
the parameter submenu by rotating and confirm by briefly
pressing.
The System submenu Print delay is displayed.
6. Call the Divider menu point by rotating and select by
touching.
7. Set the desired value by rotating and confirm by touching.
8. Call the Intensity menu by rotating and confirm by touching.
Set the value and confirm by touching.