EasyManua.ls Logo

Wecon VD2F-010SA1P - Page 77

Default Icon
133 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wecon VD2 SA Series Servo Drives Manual (Lite V1.1)
WECON technology Co., Ltd
71
P05-04
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
AI_1 zero drift
Operation
setting
Effective
immediately
0
-500 to 500
Analog
input
mV
Set the zero drift of AI_1 channel analog. zero drift is the sample voltage co voltage relative to GND when
analog channel voltage is 0.
P05-05
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
AI_2 input bias
Operation
setting
Effective
immediately
0
-5000 to
5000
Analog
input
mV
P05-06
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
AI_2 input filter
time constant
Operation
setting
Effective
immediately
200
0 to 60000
Analog
input
0.01ms
P05-07
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
AI_2 dead zone
Operation
setting
Effective
immediately
20
0 to 500
Analog
input
mV
P05-08
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
AI_2 zero drift
Operation
setting
Effective
immediately
0
-500 to 500
Analog
input
mV
indicates that the VD2F servo drive does not support this function code.
P05-09
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
Analog 10V
corresponds to the
speed value
Shutdown
setting
Effective
immediately
3000
1000 to
4500
Analog
input
rpm

Table of Contents

Related product manuals