P07-21
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
The 4th segment
displacement
Operation
setting
Effective
immediately
10000
-2147483647 to
2147483646
-
-
P07-22
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
Maximum speed of the 4th
segment displacement
Operation
setting
Effective
immediately
100
1 to 5000
-
rpm
P07-23
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
Acceleration and
deceleration time of the
4th segment displacement
Operation
setting
Effective
immediately
100
1 to 65535
-
ms
P07-24
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
Waiting time after
completion of the 4th
segment displacement
Operation
setting
Effective
immediately
100
1 to
65535
-
Set by
P07-06
P07-25
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
The 5th segment
displacement
Operation
setting
Effective
immediately
10000
-2147483647 to
2147483646
-
-
P07-26
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
Maximum speed of the 5th
segment displacement
Operation
setting
Effective
immediately
100
1 to 5000
-
rpm
P07-27
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
Acceleration and
deceleration time of the
5th segment displacement
Operation
setting
Effective
immediately
100
1 to 65535
-
ms
P07-28
Parameter name
Setting method
Effective time
Default
Range
Category
Unit
Waiting time after
completion of the 5th
segment displacement
Operation
setting
Effective
immediately
100
1 to
65535
-
Set by
P07-06
P07-29
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
The 6th segment
displacement
Operation
setting
Effective
immediately
10000
-2147483647 to
2147483646
-
-
P07-30
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
Maximum speed of the 6th
segment displacement
Operation
setting
Effective
immediately
100
1 to 5000
-
rpm
P07-31
Parameter name
Setting
method
Effective
time
Default
Range
Category
Unit
Acceleration and
deceleration time of the
6th segment displacement
Operation
setting
Effective
immediately
100
1 to 65535
-
ms