25
Wegaconcept
Technical manual
ENGLISH
19.2 Automatic heating and foaming
Proceed as follows:
t Immerge the tips of the autosteamer
(13) into the beverage;
t press the
or key, depending
on the dose of milk in the jug;
t wait until the delivery is nished;
t when the delivery is nished, the milk
will be foamed and heated at the preset
temperature.
t To stop delivery in advance, press the same key again;
t to prolong the delivery of steam, use the “Manual
steam” key
.
13
A
To increase or decrease the consistency of the foam,
slightly adjust the special regulator (A). Turning it
clockwise will decrease the consistency, while turning
it counter-clockwise will increase it.
Always proceed by performing slight adjustments.
19.3 Automatic heating
Proceed as follows:
t Immerge the tips of the autosteamer (13) into the
beverage;
t press the key
;
t wait until the delivery is nished;
t once the delivery is nished, the milk will be heated
at the programmed temperature, but not foamed.
t To stop delivery in advance, press the same key again;
t to prolong the delivery of steam, use the “Manual
steam” key
.
19.4 Manual heating and foaming
This control allows the user to use the autosteamer
nozzle manually like a normal steam nozzle.
Proceed as follows:
t Immerge the tips of the autosteamer (13) into the
beverage;
t press the
key;
t To stop delivery, press the same key again.
19.5 Automatic autosteamer nozzle
cleaning.
After 120 minutes of idle time the automatic cleaning
of the nozzle starts, lasting 15 seconds.
The following message will appear on the display:
"STEAM CLEANING CYCLE"
A minimum amount of steam will come out of the
nozzle.
!
The autosteamer foaming is factory-adjusted during
the testing phase of the machine. Therefore, it is
recommended to modify the adjustment only if
strictly necessary.
!
Before using the steam to heat beverages or to
foam milk, you should rst let some steam o until
all the condensation water is released
.
!
The use of the steam delivery point (steam nozzle),
must always be preceded by condensation draining
for at least 2 seconds.