Wegaconcept
Technical manual
ENGLISH
7
32.2 Alarm reset
To reset the counters of the doser alarms, proceed
as follows:
t insert the USB drive in the
programming reader (7);
t hold down the ENTER but-
ton for at least 5 seconds.
t scroll the menu until the
item “10 COUNTERS is high-
lighted.
t press ENTER to view the
menu
t press () repeat-
edly to reach
alarms page;
t press () to re-
set the alarms;
t confirm by
pressing () for
3 seconds.
32.3 Resetting groups washing counter
See par. 28.18 .
32.4 Water liters count for softener
regeneration reset
See par. 29.2.
32.5 Cycle count for planned service reset
See chap. 30.2 .
32.6 Ground coee kg count reset
See chap. 30.3 .
09 FILTER REGENERAT.
10 COUNTERS
11 CLOCK SETUP
12 WORKING DAYS
XX - DDMMYY XX - DDMMYY
XX - DDMMYY XX - DDMMYY
XX - DDMMYY XX - DDMMYY
XX - DDMMYY XX - DDMMYY
RESET COUNTS?
PRESS KEY ^ 3 SEC