55
Wegaconcept
Technical manual
ENGLISH
k1 k2 k3 k4 k5 k6 kC
Key - value correspondence on the display
i
Setting the "GRINDERS WEAR" threshold to 0, the
system will not perform any reporting.
i
By setting one or more dose-keys to 0, those keys
will not be counted.
!
The system operates only if the machine is paired
with a single grinder.
Press () to view the key-dose grammage screen.
k1 gr.00 k4 gr.00
k2 gr.00 k5 gr.00
k3 gr.00 k6 gr.00
kC gr.00
ENTER
Press the ENTER key, the value referred to the "k1" key
will ash.

Enter the amount in grams of ground coee per pro-
grammed dose using the key () or () .
The available range is: 0 ÷ 22 g.
k1 gr.00 k4 gr.00
k2 gr.00 k5 gr.00
k3 gr.00 k6 gr.00
kC gr.00
ENTER
Conrm by pressing ENTER, the system will switch to
the next data. Repeat the previous step until all the
dose keys are set.
Once you set the limit threshold in kg of coee, you
must set each beverage key and assign the correct
weight of ground coee used to it.
After completing this operation, during in the use, the
count will be increased by the dose set for each drink,
with every coee delivery.
Setting example:
K1 gr.07 (Single espresso) K4 gr.14 (Double medium)
K2 gr.14 (Double espresso) K5 gr.07 (Single long)
K3 gr.07 (Single medium) K6 gr.14 (Double long)
kC gr.07 (Continuous)
Upon reaching the amount of kg set as the threshold,
the system will show a message on the display (bottom
row), reminding the user to carry out the replacement
of the grinding of the coee grinder-doser.
Display the screen below.
WEAR ABD BLADES
kg XXXX/YYYY
Press the key () .
RESET ALARMS
PRESS KEY ^ 3 SEC
conrm by pressing () for 3 seconds.
Reset
To reset the used kg counter proceed as follows: