3.1 Debugging Steps
(1) Refer to Chapter 3.5 Adjustment of Port Polarity
for adjusting polarity of I/O ports
Debugging starts
(3) Refer to Chapter 3.3 Returning to Machine
Origin for returning to machine origin
Port detecting is correct or not?
Returning to machine origin is
correct or not?
(4) Refer to Chapter 3.4 Spindle Parameters
Adjustment for adjusting spindle parameters
Be satisfied with debugging
results or not?
Motion is steady or not?
(5) Refer to Chapter 3.9 Adjustment of Velocity &
Acceleration for velocity adjustment
(6) Refer to Chapter 3.6 Tool Measurement&
Chapter 3.7 Offset Setting for setting workpiece
coordinate system (WCS)
The setting of WCS is suitable
or not?
Debugging ends, ready for machining
Machine motion dimension is
correct or not?
(2) Refer to Chapter 3.2 Adjustment of Axial Direction
& Pulse Equivalent for axial direction, pulse
equivalent and workbench stroke range setting
True
True
True
True
True
True
False
False
False
False
False
False
Fig. 3-1 Debugging steps

Table of Contents

Other manuals for WEIHONG 200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEIHONG 200 Series and is the answer not in the manual?

WEIHONG 200 Series Specifications

General IconGeneral
BrandWEIHONG
Model200 Series
CategoryControl Systems
LanguageEnglish

Related product manuals