4 Do Step 2 and Step 3 again for each cylinder.
5 Write the applicable data on the oil analysis form (for example operation conditions, fuel
parameters, cylinder lubricating feed rate).
6 Do an oil analysis of the samples on-board. The oil analysis must include the data that
follows:
Residual BN
Iron (Fe) content (if possible).
7 If necessary, do the applicable recommended procedures, refer to section [section not
applicable for this engine] or to the document “Lubricants” on the WinGD website
(https://www.wingd.com/).
8 Send the oil samples to a laboratory for an oil analysis.
8.1 Make sure that the sample bottles are tightly closed.
8.2 Put the sample bottles in an applicable package.
9 Compare the oil analysis from the laboratory with the oil analysis from on-board.
10 If the oil analyses are different, do the applicable recommended procedures related to
the oil analysis from the laboratory, refer to section [section not applicable for this
engine] or to the document “Lubricants” on the WinGD website (https://
www.wingd.com/).