EasyManua.ls Logo

WinGD X92DF - Servo Oil Leakage Flow from the Servo Oil Supply Unit Is too High; Servo Oil Flow at a Servo Oil Pump Inlet Is too Low; Bearing Oil Temperature at a Bearing Outlet Is too High; Oil Mist Concentration Is too High

WinGD X92DF
608 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tab 10-12 Servo oil leakage flow from the servo oil supply unit is too high
Indication Possible cause Procedure
LS2055A The servo oil unit or a servo oil
pipe is defective
Find the cause and repair the fault, refer to
section 10.3 Examine the supply unit for
servo oil leakage.
Tab 10-13 Servo oil flow at a servo oil pump inlet is too low
Indication Possible cause Procedure
FS2061-nnA The related servo oil pump is de-
fective
Replace the defective servo oil pump as
soon as possible.
The alarm has an effect only above 30% of engine load.
Tab 10-14 Bearing oil temperature at a bearing outlet is too high
Indication Possible cause Procedure
TE2101-nnA
TE2201-nnA
TE2301-nnA
This is a result of the malfunction
in Table 10-7 - Lubricating oil sup-
ply pressure at the engine inlet is
too low
Do the repair shown there.
A bearing is defective
Find the cause and repair the fault.
The oil does not have the speci-
fied properties
Use correct oil.
Tab 10-15 Oil mist concentration is too high
Indication Possible cause Procedure
AE2401-nnA
(crankcase)
AE2415A (gear-
case)
AE2421-nnA (fuel
supply unit)
The oil supply system is defective
Find the cause and repair the fault.
Parts that move have become too
hot
As a temporary procedure, decrease the
engine load.
Stop the engine.
Wait a minimum of 20 minutes to let the
engine temperature decrease.
Find the cause and repair the fault.
X92DF
AA00-0000-00AAA-410C-A
Operation Manual Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 518 - Issue 002 2020-08

Table of Contents