9.7 Running-in of new components - general
After an overhaul or an installation of new components of the piston running system, WinGD
recommends a running-in procedure. This makes sure a correct film of cylinder oil on the piston
running system is built. The procedure includes a temporary higher feed rate, refer to Figure
9-3.
WinGD recommends an inspection of the cylinder liners and of the piston rings after 24
operation hours and after 72 operation hours (001, Figure 9-3). For this running-in procedure it
is not necessary to have a special loading up apart from vessel specific loading up protocols.
Fig 9-3 Feed rate adjustments - running-in
001
001
X92DF
AA00-0000-00AAA-950B-A
Operation Manual Running-in of new components - general
Winterthur Gas & Diesel Ltd.
- 504 - Issue 002 2020-08