EasyManuals Logo

Xerox WorkCentre 3119 Service Manual

Xerox WorkCentre 3119
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #128 background imageLoading...
Page #128 background image
General Procedures and Information
6-18 06/06 WorkCentre 3119
Optical Resolution: 600 x 600 dpi
Copy Quality - H x V: Text : 600 x 300 dpi (default)
(User selectable via Content button) :Mixed : 600 x 300 dpi, Photo : 600 x 600 dpi
Supported Media Types: Plain, Label, Cardstock, Transparency
Copy Speed: Platen, SDMP: 19cpm (Letter) (SDMP = Single Document, Multiple Printout)
Reduce/Enlarge: Platen: 50% - 200% (1% increments)
Non-printable Area: 4 mm (Top, Bottom, and each Side)
Copy Count: 1 to 99 (Page count displayed on LCD during copy operation)
Copy Modes: Text, Text/Photo, Photo
Fixed R/E Setting: 100%, Auto-fit
Darkness Control: 3 levels
First Copy Output Time (FCOT): Platen: 11 sec. (600 x 300 dpi)
Duplex Copy Manual
Power supply
1. SMPS & HVPS
The SMPS and HVPS are combined together as a single board.
The SMPS supplies DC Power to the entire system. It takes 110V/220V and outputs the +5V,
+24V to supply the power to the Main PBA.
The HVPS board creates the high voltage of THV/MHV/Supply/Dev and supplies it to the devel-
oper part for making best condition to display the image. The HVPS part takes the 24V and out-
puts the high voltage for THV/MHV/BIAS, and the outputted high voltage is supplied to the toner,
OPC cartridge, and transfer roller.
2. HVPS (High Voltage Power Supply)
Transfer High Voltage (THV+)
- Input Voltage : 24 V DC 15%
- Output Voltage : MAX +5.0KV 5 %,(Duty Variable, no loading )
- Input contrast of the Voltage stability degree : under 3 % (fluctuating input 21.6V-26.4V)
Loading contrast : 3 % or less
- Output Voltage Rising Time : 100 ms Max
- Output Voltage Falling Time : 100 ms Max
- Fluctuating transfer voltage with environmental various : +650 V- 5 KV
- Environment Recognition Control Method : The THV-PWM ACTIVE is transfer active sig-
nal. It detects the resistance by recognizing the voltage value, F/B, while permits the envi-
ronmental recognition voltage.
- Output Voltage Control Method : Transfer Output Voltage is outputted and controlled by
changing Duty of THVPWM Signal.
Charge Voltage (MHV)
- Input Voltage : 24 V DC 15%
- Output Voltage : -1.3KV to -1.8KV DC 3%
- Output Voltage Rising Time : 50 ms Max
- Output Voltage Falling Time : 50 ms Max
- Output Loading range : 30 M - 1000 M
- Output Control Signal(MHV-PWM) : CPU is HV output when PWM is Low

Table of Contents

Other manuals for Xerox WorkCentre 3119

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox WorkCentre 3119 and is the answer not in the manual?

Xerox WorkCentre 3119 Specifications

General IconGeneral
Print TechnologyLaser
Print Speed19 ppm
Print Resolution600 x 600 dpi
Copy Speed19 cpm
Copy Resolution600 x 600 dpi
Paper Capacity250 sheets
ConnectivityUSB 2.0
FunctionsPrint, Copy, Scan
Scanner TypeFlatbed
Memory (Standard)32 MB
Operating System CompatibilityWindows, Mac