January 2016
2-54
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
07-620, 630, 640
Status Indicator RAPs
10. Perform the OF5 Main PWB Check RAP.
4250/4260/4265 With an HCF
Refer to Wiring Diagram 30 and Wiring Diagram 31. Perform the following:
1. Make sure the tray access door, PL 7.50 Item 5 is closed.
2. Open the tray access door, PL 7.50 Item 5. Check for obstructions behind the access
door.
3. Check that the HCF door sensor actuator on the paper guide, PL 7.50 Item 3 is not miss-
ing or damaged.
4. Enter dC330 code 08-300. Check the T3 door sensor (Q08-300), PL 7.65 Item 14.
5. Check the wiring between the door sensor and CN10 on the HCF PWB. If necessary,
install a new door sensor, PL 7.65 Item 14.
6. (4250/4260) Check the wiring between CN1 on the HCF PWB and CN19 on the Main
PWB.
7. (4265) Check the wiring between CN1 on the HCF PWB and CN34 on the Main PWB.
8. If necessary, install a new HCF PWB, PL 7.60 Item 7.
9. Perform the OF5 Main PWB Check RAP.