January 2016
2-60
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
08-610
Status Indicator RAPs
08-610 Duplex Jam 1 RAP
08-610 The lead edge of the document failed to actuate the duplex jam 1 sensor within the cor-
rect time in reverse mode.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: The main PWB has test points. The location of the test points is shown on the following
PJ location illustrations:
• 4150 Main PWB.
• 4250/4260 Main PWB.
• 4265 Main PWB.
NOTE: The side cover assembly interlock switch must be closed to supply +24V to the motors
and clutches.
Refer to:
• (4150) Wiring Diagram 3 and Wiring Diagram 7.
• (4250/4260) Wiring Diagram 22, Wiring Diagram 24 and Wiring Diagram 25.
• (4265) Wiring Diagram 38, Wiring Diagram 40 and Wiring Diagram 41.
Perform the following:
1. Open the right hand cover. Remove all jammed paper.
2. Unclip the duplex assembly, PL 7.30 Item 20. Check that the paper path is clear and not
damaged.
3. Check that the duplex jam 1 sensor actuator, PL 7.30 Item 20 moves freely and is not
damaged.
4. Enter dC330 code 08-700. Check the duplex jam 1 sensor (Q08-700), PL 7.30 Item 18.
5. (4150) Check the wiring between the duplex jam 1 sensor and CN25 on the Main PWB. If
necessary, install a new duplex jam 1 sensor, PL 7.30 Item 18.
6. (4250/4260) Check the wiring between the duplex jam 1 sensor and CN17 on the Main
PWB. If necessary, install a new duplex jam 1 sensor, PL 7.30 Item 18.
7. (4265) Check the wiring between the duplex jam 1 sensor and CN31 on the Main PWB. If
necessary, install a new duplex jam 1 sensor, PL 7.30 Item 18.
8. Enter dC330 code 04-300, then code 04-310. Check that the duplex motor (MOT04-300),
PL 10.20 Item 2, runs in forward and reverse and drives the duplex roll, PL 10.15 Item 22.
9. (4150) Check the wiring between the duplex motor and CN12 on the Main PWB. Install
new components as necessary, PL 10.15 and PL 10.20.
10. (4250/4260)
Check the wiring between the duplex motor and CN13 on the Main PWB.
Install new components as necessary, PL 10.15 and PL 10.20.
11. (4265) Check the wiring between the duplex motor and CN28 on the Main PWB. Install
new components as necessary, PL 10.15 and PL 10.20.
12. Enter dC330 code 08-870. Check that the duplex gate solenoid (SOL08-870), PL 10.15
Item 4 energises and lowers the duplex gate, PL 10.15 Item 15.
13. Check the duplex gate for damage. If necessary, install a new duplex gate, PL 10.15 Item
15.
14. (4150) Check the wiring between the duplex gate solenoid and CN6 on the Main PWB. If
necessary, install a new duplex gate solenoid, PL 10.15 Item 4.
15. (4250/4260) Check the wiring between the duplex gate solenoid and CN8 on the Main
PWB. If necessary, install a new duplex gate solenoid, PL 10.15 Item 4.
16. (4265) Check the wiring between the duplex gate solenoid and CN2 on the Main PWB. If
necessary, install a new duplex gate solenoid, PL 10.15 Item 4.
17. Check that the following components are clean and rotate freely:
• Duplex roll, PL 10.15 Item 22.
• Duplex roll idlers, PL 10.15 Item 9.
18. If necessary, install new components:
• Exit assembly, PL 10.15 Item 1.
• Side cover assembly, PL 7.30 Item 1.
19. Perform the OF5 Main PWB Check RAP.