January 2016
2-61
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
08-620
Status Indicator RAPs
08-620 Duplex Jam 2 RAP
08-620 The lead edge of the document failed to actuate the duplex jam 2 sensor within the cor-
rect time.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
NOTE: The main PWB has test points. The location of the test points is shown on the following
PJ location illustrations:
• 4150 Main PWB.
• 4250/4260 Main PWB.
• 4265 Main PWB.
NOTE: The side cover assembly interlock switch must be closed to supply +24V to the motors
and clutches.
Refer to:
• (4150) Wiring Diagram 5 and Wiring Diagram 7.
• (4250/4260) Wiring Diagram 24 and Wiring Diagram 25.
• (4265) Wiring Diagram 40 and Wiring Diagram 41.
Perform the following:
1. Open the right hand cover. Remove all jammed paper.
2. Check that the paper path is clear and not damaged.
3. Check that the duplex jam 2 sensor actuator, PL 8.15 Item 10 moves freely and is not
damaged.
4. Enter dC330 code 08-710. Check the duplex jam 2 sensor (Q08-710), PL 8.15 Item 8.
5. (4150) Check the wiring between the duplex jam 2 sensor and CN13 on the Main PWB. If
necessary, install a new duplex jam 2 sensor, PL 8.15 Item 8.
6. (4250/4260) Check the wiring between the duplex jam 2 sensor and CN12 on the Main
PWB. If necessary, install a new duplex jam 2 sensor, PL 8.15 Item 8.
7. (4265) Check the wiring between the duplex jam 2 sensor and CN27 on the Main PWB. If
necessary, install a new duplex jam 2 sensor, PL 8.15 Item 8.
8. Enter dC330 code 04-100 to run the main BLDC motor.
9. Enter dC330 code 08-860 to energize the duplex feed clutch (CL08-860), PL 7.30 Item 4.
Manually rotate the drive gear on the duplex feed clutch. Check that the duplex feed rolls,
PL 7.30 Item 10 and PL 7.30 Item 12 are clean and rotate freely. Install new components
as necessary.
10. (4150) Check the wiring between the duplex feed clutch and CN25 on the Main PWB.
Install new components as necessary, PL 7.30.
11. (4250/4260) Check the wiring between the duplex feed clutch and CN17 on the Main
PWB. Install new components as necessary,
PL 7.30.
12. (4265) Check the wiring between the duplex feed clutch and CN31 on the Main PWB.
Install new components as necessary, PL 7.30.
13. Check that the duplex feed roll idlers, PL 7.35 Item 6 are clean and rotate freely. Install
new components as necessary, PL 7.35.
14. If necessary, install a new side cover assembly, PL 7.30 Item 1.
15. Perform the OF5 Main PWB Check RAP.