EasyManua.ls Logo

Xerox WorkCentre 4150

Xerox WorkCentre 4150
631 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2016
2-3
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
01-100
Status Indicator RAPs
01-100 Side Cover Assembly Open RAP
01-100 The machine has detected that the side cover assembly is open. When the cover is
open, there is no +24V supply to the motors or the HVPS.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Go to the relevant procedure:
4150 Checkout
4250/4260/4265 Checkout
4150 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the Main
PWB PJ location illustration.
Refer to Wiring Diagram 4 and Wiring Diagram 8. Perform the following:
1. Switch off the machine, then switch on the machine.
2. Check that the interlock switch actuator on the side cover assembly, PL 7.30 Item 1 is not
missing or damaged.
3. Check that the side cover assembly closes correctly.
4. Enter dC330 code 01-100. Check the side cover interlock switch assembly (S01-100), PL
4.15 Item 12.
5. Check the wiring between the side cover interlock switch and CN8 on the Main PWB. If
necessary, install a side cover interlock switch assembly, PL 4.15 Item 12.
6. Check for +24V between CON71 on Power Supply Unit 1 and CN27 on the Main PWB. If
necessary, install a new power supply unit 1, PL 1.10 Item 3.
7. Perform the OF5 Main PWB Check RAP.
4250/4260/4265 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the Main
PWB PJ location illustration.
Refer to (4250/4260) Wiring Diagram 17 and Wiring Diagram 22, (4265) Wiring Diagram 33and
Wiring Diagram 38.
1. Switch off the machine, then switch on the machine.
2. Check that the interlock switch actuator on the side cover assembly, PL 7.30 Item 1 is not
missing or damaged.
3. Check that the side cover assembly closes correctly.
4. Enter dC330 code 01-100. Check the side cover interlock switch assembly (S01-100), PL
4.15 Item 12.
5. (4250/4260) Check the wiring between the side cover interlock switch and CN9 on the
Main PWB. If necessary, install a side cover interlock switch assembly, PL 4.15 Item 12.
6. Check for +24V between CON71 on Power Supply Unit 1 and CN27 on the Main PWB. If
necessary, install a new power supply unit 1, PL 1.15 Item 3.
7. (4265) Check the wiring between the side interlock sensor and CN 18 on the Main PWBIf
necessry, install a side cover interlock switch assembly, PL 4.15.
8. Check for +24V between CON71 on Power Supply Unit 1 and CN33 on the Main PWB. If
necessary, install a new power supply unit 1, PL 1.15 Item 3.
9. Perform the OF5 Main PWB Check RAP.

Table of Contents

Other manuals for Xerox WorkCentre 4150

Related product manuals