January 2016
2-17
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
03-700, 03-800
Status Indicator RAPs
03-700 Check Fax Kit RAP
03-700 The machine has detected a fault with the fax module.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Go to the relevant procedure:
4150 Checkout
4250/4260 Checkout
4265 Checkout
4150 Checkout
Refer to Wiring Diagram 5. Perform the following:
1. Ensure the fax module, PL 1.10 Item 14 is correctly installed.
2. If necessary, install a new fax PWB, PL 20.10 Item 4.
3. Perform the OF5 Main PWB Check RAP.
4250/4260 Checkout
Refer to Wiring Diagram 27. Perform the following:
1. Ensure the fax module, PL 1.15 Item 14 is correctly installed.
2. If necessary, install a new fax PWB, PL 1.15 Item 14.
3. Perform the OF5 Main PWB Check RAP.
4265 Checkout
Refer to Wiring Diagram 43. Perform the following:
1. Ensure the fax module, PL 1.15 Item 14 is correctly installed.
2. If necessary, install a new fax PWB, PL 1.15 Item 14.
3. Perform the OF5 Main PWB Check RAP.
03-800 Check HDD RAP
03-800 The machine has detected a fault with the hard disk drive (HDD).
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Go to the relevant procedure:
4150 Checkout
4250/4260 Checkout
4265 Checkout
4150 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the Main
PWB PJ location illustration.
Refer to Wiring Diagram 6. Perform the following:
1. Switch off the machine, then switch on the machine.
2. Check that the HDD PWB, PL 1.10 Item 17 is securely connected to CN20 on the Main
PWB.
3. Check that the HDD ribbon cable, PL 1.10 Item 18 is securely connected to the HDD
PWB and the HDD.
4. Reset the main PWB. Perform the following:
a. Disconnect the battery, PL 1.10 Item 5 from CN29 on the Main PWB.
b. Set a multimeter to VDC.
c. Use the multimeter to discharge the voltage across the pins at CN29.
NOTE: It will take approximately 1 minute to discharge the voltage.
d. Reconnect the battery.
5. Switch off the machine. Disconnect the HDD PWB, PL 1.10 Item 17 from the main PWB.
Switch on the machine. If the machine boots up, install new components as necessary:
HDD harness, PL 1.10 Item 18.
HDD PWB, PL 1.10 Item 17.
HDD, PL 1.10 Item 11.
6. Perform the OF5 Main PWB Check RAP.
4250/4260 Checkout
NOTE: The main PWB has 4 test points, GND, +3.3V, +5V and +24V. The location of the test
points is shown on the Main PWB PJ location illustration.
Refer to Wiring Diagram 26. Perform the following:
1. Switch off the machine, then switch on the machine.
2. Check that the HDD, PL 1.15 Item 11 is securely connected to CN20 and CN21 on the
Main PWB.
3. Format the hard disk, refer to GP 20 Format Hard Disk (4250/4260).