Loading...
168
4-9-10TAN [TAN]
1. Summary
TAN [TAN]
16 bits
-
32 bits
TAN
Execution
condition
Normally ON/OFF,
rising/falling edge
Suitable
Models
XD, XL
Hardware
requirement
-
Software
requirement
-
2. Operands
Operands
Function
Data Type
S
Soft element address need to do tan
32bit,BIN
D
Result address
32bit,BIN
3. Suitable soft components
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD;
DM includes DM, DHM; DS includes DS, DHS.
TAN D50 D60
X0
S· D·
This instruction performs the mathematical TAN operation on the floating point value in S.
The result is stored in D.
D51 D50
D61 D60
S·
D·
Note: Before the instruction is executed, the data in parameter S must be floating number;
otherwise, the execution result will be wrong.
Word
Operand
System
Constant
Module
D
*
FD
TD
*
CD
*
DX
DY
DM
*
DS
*
K /H
ID
QD
S
D
Description
(D51,D50) RAD → (D61,D60) TAN
Binary Floating Binary Floating
RAD value (angle× π/180)
Assign the binary floating value
TAN value
Binary Floating

Table of Contents