345
is Y2. To improve the speed changing precision, the acceleration and deceleartion time are 0.
The speed will switch by external interruption.
Segment
Frequency setting
value (Hz)
Pulse numbers
Origin ---- A
10000
999999999
A---- B
30000
999999999
B ----- C
20000
999999999
Acceleration
and deceleratoin
time
0
Note: as the pulse numbers of each segment is unknown, the pulse numbers should set large
enough to ensure the object can move to the proximity switch. The STOP instruction will be
run by external interruption when the object gets to position C.
Component explanation
PLC
component
Control explanation
Mark
M0
Start button, PLSF will send pulse when the
button is pressed
HD0
the PLSF pulse frequency register
Program

Table of Contents