CAT-1 RATE
Function: Sets the baud rate for a CAT command
input of the USB jack (Enhanced COM
Port).
Available Values: 4800 / 9600 / 19200 / 38400 /
115200 bps
Default Setting: 38400 bps
CAT-1 TIME OUT TIMER
Function: Sets the Time-Out Timer for a CAT
command input.
Available Values: 10 / 100 / 1000 / 3000 (msec)
Default Setting: 10 msec
Description: Sets the Time-Out Timer countdown
time for a CAT command input of the
USB jack (Enhanced COM Port).
CAT-1 CAT-3 STOP BIT
Function: Stop bit setting when operating with
CAT-1 and CAT-3. The stop bit of CAT-
2 is “1bit” and cannot be “2bit”.
Available Values: 1bit / 2bit
Default Setting: 1bit
CAT-2 RATE
Function: Sets the baud rate for a CAT-2 com-
mand input of the USB jack (Standard
COM Port).
Available Values: 4800 / 9600 / 19200 / 38400 /
115200 bps
Default Setting: 4800 bps
CAT-2 TIME OUT TIMER
Function: Sets the Time-Out Timer for a CAT-2
command input.
Available Values: 10 / 100 / 1000 / 3000 (msec)
Default Setting: 10 msec
Description: Sets the Time-Out Timer countdown
time for a CAT-2 command input of
the USB jack (Standard COM Port).
CAT-3 RATE
Function: Sets the baud rate for a CAT-3 com-
mand input of the TUNER/LINEAR
jack.
Available Values: 4800 / 9600 / 19200 / 38400 /
115200 bps
Default Setting: 38400 bps
CAT-3 TIME OUT TIMER
Function: Sets the Time-Out Timer for a CAT-3
command input.
Available Values: 10 / 100 / 1000 / 3000 (msec)
Default Setting: 10 msec
Description: Sets the Time-Out Timer countdown
time for a CAT-3 command input of
the TUNER/LINEAR jack.
QMB CH
Function: Number of channels setting of the
Quick Memory bank.
Available Values: 5ch / 10ch
Default Setting: 5ch
Description: Set the number of channels that can
be registered in the Quick Memory
Bank.
BAND STACK
Function: Enable/Disable the band stack func-
tion.
Available Values: OFF / ON
Default Setting: ON
Description:
ON: Enable the band stack function.
OFF: Disable the band stack function.
MEM GROUP
Function: Sets the memory group function.
Available Values: OFF / ON
Default Setting: OFF
Description: Set this setting to “ON” to divide the
memory channels into 6 groups.
TX TIME OUT TIMER
Function: Sets the Time-Out Timer countdown
time.
Available Values: OFF / 1 - 30 min
Default Setting: OFF (10 min, European Version)
Description: When the time-out timer function
is active, a beep is emitted when a
continuous transmission nears the
set time. About 10 seconds later, the
transceiver is forced to return to the
receiving mode.
MIC SCAN
Function: Activates the microphone automatic
scanning function.
Available Values: OFF / ON
Default Setting: ON
Description: Sets the operation of the UP/DWN
keys on the microphone.
ON: Starts scanning automatically by pressing
and holding the UP/DWN key for 1 second
or more (Scanning continues even after
releasing the button). To stop scanning,
press the UP/DWN key again briefly or
press the PTT button to transmit.
OFF: Scans only while pressing and holding the
UP/DWN key. To stop scanning, release
the button.