2.2  b: Application
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide  113
■ b3-06: Output Current 1 during Speed Search (Speed Estimation)
Sets the current injected to the motor at the beginning of Speed Estimation Speed Search as a factor of the motor rated 
current set in E2-01 (E4-01 for motor 2). If the motor speed is relatively slow when the drive starts to perform Speed 
Search after a long period of baseblock, it may be helpful to increase the setting value. The output current during Speed 
Search is automatically limited by the drive rated current.
Note: Use Current Injection if Speed Estimation is not working correctly even after adjusting b3-06. Refer to Step 2: Current Injection 
on page 110 for details.
■ b3-07: Output Current 2 during Speed Search (Speed Estimation)
Sets the current injected to the motor at the beginning of Speed Estimation Speed Search as a factor of the motor no-load 
current set in E2-03 (E4-03 for motor 2).
If, when a Speed Estimation search is performed, the estimation result is the minimum output frequency, increase the set 
value in increments of 0.1.
■
b3-10: Speed Search Detection Compensation Gain (Speed Estimation)
Sets the gain for the detected motor speed of the Speed Estimation Speed Search. Increase the setting only if an 
overvoltage fault occurs when the drive restarts the motor.
■
b3-11: Speed Search Method Switching Level (Speed Estimation)
Sets the switching level when the search method is automatically selected in accordance with the size of the residual 
voltage of the motor.
■
b3-12: Current Detection Dead-Band Width during Speed Search (Speed Estimation)
Sets the dead-band width for the current detected in a Speed Search. If the estimation result is the lowest output 
frequency when Speed Estimation Speed Search is performed, increase the set value in increments of 0.1.
■
b3-17: Speed Search Restart Current Level
Sets the current level at which Speed Estimation is restarted as a percentage of the drive rated current to avoid 
overcurrent and overvoltage problems since a large current can flow into the drive if the difference between the estimated 
frequency and the actual motor speed is too large when performing Speed Estimation.
No.
<1> Refer to Defaults by Drive Model Selection (o2-04) on page 87 for details on default settings.
Name Setting Range Default
b3-06 Output Current 1 during Speed Search (Speed Estimation) 0.0 to 2.0 Determined by o2-04 <1>
No. Name Setting Range Default
b3-07 Output Current 2 during Speed Search (Speed Estimation) 0.0 to 3.0 2.0
No. Name Setting Range Default
b3-10
Speed Search Detection Compensation Gain
(Speed Estimation)
1.00 to 1.20 1.05
No.
<1> Refer to Defaults by Drive Model Selection (o2-04) on page 87 for details on default settings.
Name Setting Range Default
b3-11
Speed Search Method Switching Level 
(Speed Estimation)
0.5 to 100.0 Determined by o2-04 <1>
No. Name Setting Range Default
b3-12
Current Detection Dead-Band Width during Speed Search 
(Speed Estimation)
2.0 to 20.0 8.0
No. Name Setting Range Default
b3-17 Speed Search Restart Current Level 0 to 200% 120%
MV1000ParameterGuide_E_conditional_chap2-2.fm  113 ページ  2013年10月16日 水曜日 午前10時49分