238 YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide
2.11 U: Monitor Parameters
2.11 U: Monitor Parameters
Monitor parameters let the user view various aspects of drive performance using the digital operator display. Some
monitors can be output from output terminals 1 to 4 by assigning the specific monitor parameter number to H4-01,
H4-11, H4-21, and H4-31. Refer to H4-01, H4-11, H4-21, H4-31: Analog Output 1, 2, 3, 4 Monitor Selections on
page 198 for details on assigning functions to an analog output.
Analog output option card AO-A3 also lets the user view various aspects of drive performance.
u U1: Operation Status Monitors
Status monitors display drive status data such as output frequency and output current. Refer to U1: Operation Status
Monitors on page 76 for a complete list of U1- monitors and descriptions.
u U2: Fault Trace
These monitor parameters are used to view various drive statuses when a fault occurs.
This information is helpful for finding out why a fault occurred. Refer to U2: Fault Trace on page 79 for a complete list
of U2- monitors and descriptions.
U2- monitors are not reset when the drive is initialized. Refer to o4-11: U2, U3 Initialization on page 236 for
instructions on how to reset these monitor values.
Note: Fault trace (i.e., the fault history) is not kept when CPF00, CPF01, Uv1, Uv2 occur.
u U3: Fault History
These parameters display faults that have occurred during operation as well as the drive operation time when those faults
occurred. Refer to U3: Fault History on page 80 for a complete list of U3- monitors and descriptions.
U3- monitors are not reset when the drive is initialized. Refer to o4-11: U2, U3 Initialization on page 236 for
instructions on how to reset these monitor values.
Note: Fault trace (i.e., the fault history) is not kept when CPF00, CPF01, Uv1, Uv2 occur.
u U4: Maintenance Monitors
Maintenance monitors show:
•kWh data
Highest peak current that has occurred and output frequency at the time the peak current occurred
Motor overload status information
Detailed information about the present Run command and frequency reference source selection
Refer to U4: Maintenance Monitors on page 80 for a complete list of U4- monitors and descriptions.
u U5: PID Monitors
These monitors display various aspects of PID control. Refer to PID Block Diagram on page 118 for details on how
these monitors display PID data.
U5: PID Monitors on page 82 has a complete list of U5- monitors and descriptions.
MV1000ParameterGuide_E_conditional.book 238 ペー 01年1月1日 日 午後8時18分

Table of Contents

Other manuals for YASKAWA FSDrive-MV1000

Related product manuals