1.3 Parameter Table
YASKAWA ELECTRIC TOEP C710687 03B FSDrive-MV1000 Parameter Guide 49
u H: Terminal Functions
H parameters assign functions to the input and output terminals.
No.
(Addr.)
Name Description Setting Page
H1: Contact Inputs
H1-02
(439H)
Contact Input 2
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: 40
Min: 1
Max: 9F
171
H1-03
(400H)
Contact Input 3
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: 6A
Min: 0
Max: 9F
171
H1-04
(401H)
Contact Input 4
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: 70
Min: 0
Max: 9F
171
H1-05
(402H)
Contact Input 5
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: F
<43>
Min: 0
Max: 9F
171
H1-06
(403H)
Contact Input 6
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: F
Min: 0
Max: 9F
171
H1-07
(404H)
Contact Input 7
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: 14
Min: 0
Max: 9F
171
H1-08
(405H)
Contact Input 8
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: F
Min: 0
Max: 9F
171
H1-09
(406H)
Contact Input 9
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: F
Min: 0
Max: 9F
171
H1-10
(407H)
Contact Input 10
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: F
Min: 0
Max: 9F
171
H1-11
(408H)
Contact Input 11
Function Selection
Assigns a function to the contact inputs.
Refer to H1 Contact Input Selections on page 51 for a description of setting
values.
Note: Unused terminals should be set to F.
Default: F
Min: 0
Max: 9F
171