1.4 Control Mode Dependent Parameter Default Values
1.4 Control Mode Dependent Parameter Default Values
The tables below list the parameters that depend on the control mode selection (A1-02 for motor 1, E3-01 for motor 2).
Changing the control mode initializes these parameters to the values shown here.
u A1-02 (Motor 1 Control Mode) Dependent Parameters
Table 1.2 A1-02 (Motor 1 Control Mode) Dependent Parameters and Default Values
No. Name Setting Range Resolution
Control Modes (A1-02)
V/f (0) OLV (2) CLV (3)
A3-01 Trace Data 01 0 to 899 – 101 101 101
A3-02 Trace Data 02 0 to 899 – 102 102 102
A3-03 Trace Data 03 0 to 899 – 103 103 103
A3-04 Trace Data 04 0 to 899 – 106 105 105
A3-05 Trace Data 05 0 to 899 – 107 106 106
A3-06 Trace Data 06 0 to 899 – 110 107 107
A3-07 Trace Data 07 0 to 899 – 111 109 109
A3-08 Trace Data 08 0 to 899 – 112 110 110
A3-09 Trace Data 09 0 to 899 – 113 111 111
A3-10 Trace Data 10 0 to 899 – 116 112 112
A3-11 Trace Data 11 0 to 899 – 149 113 113
A3-12 Trace Data 12 0 to 899 – 152 116 116
A3-13 Trace Data 13 0 to 899 – 154 149 149
A3-14 Trace Data 14 0 to 899 – 408 152 152
A3-15 Trace Data 15 0 to 899 – 416 154 154
A3-16 Trace Data 16 0 to 899 – 418 408 408
A3-17 Trace Data 17 0 to 899 – 419 416 416
A3-18 Trace Data 18 0 to 899 – 421 418 418
A3-19 Trace Data 19 0 to 899 – 601 419 419
A3-20 Trace Data 20 0 to 899 – 618 421 421
A3-21 Trace Data 21 0 to 899 – 000 601 601
A3-22 Trace Data 22 0 to 899 – 000 602 602
A3-23 Trace Data 23 0 to 899 – 000 605 603
A3-24 Trace Data 24 0 to 899 – 000 606 604
A3-25 Trace Data 25 0 to 899 – 000 607 605
A3-26 Trace Data 26 0 to 899 – 000 608 606
A3-27 Trace Data 27 0 to 899 – 000 618 607
A3-28 Trace Data 28 0 to 899 – 000 000 608
A3-29 Trace Data 29 0 to 899 – 000 000 618
A3-30 Trace Data 30 0 to 899 – 000 000 000
A3-31 Trace Data 31 0 to 899 – 000 000 000
A3-32 Trace Data 32 0 to 899 – 000 000 000
b2-01
Zero Speed Level (DC Injection Braking
Start Frequency)
<36>
0.0 to 10.0 0.1 0.5 Hz 0.5 Hz 0.5 Hz
b2-04 DC Injection Braking Time at Stop 0.00 to 10.00 0.01 s 0.50 0.50 0.50
b3-01 Speed Search Selection at Start 0 to 1 – 0 0 –
b3-02 Speed Search Deactivation Current 0 to 200 1% 70 30 –
b5-15 PID Sleep Function Start Level 0.0 to 120.0 <20> 0.1 0.0 Hz 0.0 Hz 0.0 Hz
b6-01 Dwell Reference at Start 0.0 to 120.0 0.1 0.0 Hz 0.0 Hz 0.0 Hz
b6-03 Dwell Reference at Stop 0.0 to 120.0 <20> 0.1 0.0 Hz 0.0 Hz 0.0 Hz
C1-11 Accel/Decel Time Switching Frequency 0.0 to 120.0 0.1 0.0 Hz 0.0 Hz 0.0 Hz
C2-01 S-Curve Characteristic at Accel Start 0.00 to 10.00 0.01 s 0.20 0.20 0.20
C3-01 Slip Compensation Gain 0.0 to 2.5 0.1 0.0 1.0 1.0
C3-02 Slip Compensation Primary Delay Time 0 to 10000 1 ms 3000 3000 –
C3-05 Output Voltage Limit Operation Selection 0 to 1 – –
01
C4-01 Torque Compensation Gain 0.00 to 2.50 0.01 1.00 1.00 –
C4-02 Torque Compensation Primary Delay Time 1 0 to 10000 1 ms 200 50 –