Parameter Details
5
5.6 F: Options
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference 257
â–  F7-08: Subnet Mask 4
No.
(Hex.)
Name Description
Default
(Range)
F7-08
(03EC)
Subnet Mask 4 Sets the fourth octet of the subnet mask of the connected network. 0
(0 - 255)
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
â–  F7-09: Gateway Address 1
No.
(Hex.)
Name Description
Default
(Range)
F7-09
(03ED)
Gateway Address 1 Sets the first octet of the gateway address of the connected network. 192
(0 - 255)
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
â–  F7-10: Gateway Address 2
No.
(Hex.)
Name Description
Default
(Range)
F7-10
(03EE)
Gateway Address 2 Sets the second octet of the gateway address of the connected network. 168
(0 - 255)
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
â–  F7-11: Gateway Address 3
No.
(Hex.)
Name Description
Default
(Range)
F7-11
(03EF)
Gateway Address 3 Sets the third octet of the gateway address of the connected network. 1
(0 - 255)
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
â–  F7-12: Gateway Address 4
No.
(Hex.)
Name Description
Default
(Range)
F7-12
(03F0)
Gateway Address 4 Sets the fourth octet of the gateway address of the connected network. 1
(0 - 255)
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
â–  F7-13: Address Mode at Startup
No.
(Hex.)
Name Description
Default
(Range)
F7-13
(03F1)
Address Mode at Startup Sets the method to set option card IP addresses. 2
(0 - 2)
0 : Static
1 : BOOTP
2 : DHCP

Table of Contents

Other manuals for YASKAWA HV600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA HV600 and is the answer not in the manual?

YASKAWA HV600 Specifications

General IconGeneral
CategoryDC Drives
SeriesHV600
Overload Capacity150% for 60 seconds
Output Voltage0 - Input Voltage
EnclosureNEMA 1, NEMA 12
CommunicationEthernet/IP, Modbus, DeviceNet, Profibus
SafetySafe Torque Off (STO)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short Circuit
Humidity5-95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Control MethodVector Control

Related product manuals