YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference 353
Table 5.48 Example of Message Displays for Pre-Charge
Default (o1-82 = 0) Full Screen Message (o1-82 = 1)
Note:
• When o1-80 = 0 [OFF], drive Faults, oFAxx, or CPFs do not trigger a full-screen message to display.
• When o1-81= 0 [Alarm Screen Display = OFF], drive Alarms do not trigger a full-screen message to display.
• When o1-82 = 0 [Message Screen Display = OFF], drive Messages do not trigger a full-screen message to display. The keypad will
continue to show limit errors and other informative screens.
• You cannot select the display method of oPExx [Parameter Setting Errors]. The keypad shows oPExx errors as full screen displays and
status monitor displays. Active oPExx errors have display priority over active faults and alarms.
Status Monitor Display
When o1-40 = 0 [Home Screen Display Selection = Custom Monitor], the keypad will show the Status Monitor on
the second and third lines of the HOME screen.
• The second line shows HOA status and other information, for example:
– Fault/Alarm/oPExx/oFAxx codes
– Information Text status
• The third line shows information texts, for example:
– Pre-Charge messages
– Sleep messages
It will also show Information Text for Sequence Timer status.
Table 5.49 shows the examples of Status Monitor display during normal operation.
Table 5.49 Normal Operation Display
Custom Monitors Setting
(o1-24 to o1-35)
Display with No Message Display with Message
More than one monitor set
Only one monitor set
No monitor set

Table of Contents

Other manuals for YASKAWA HV600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA HV600 and is the answer not in the manual?

YASKAWA HV600 Specifications

General IconGeneral
CategoryDC Drives
SeriesHV600
Overload Capacity150% for 60 seconds
Output Voltage0 - Input Voltage
EnclosureNEMA 1, NEMA 12
CommunicationEthernet/IP, Modbus, DeviceNet, Profibus
SafetySafe Torque Off (STO)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short Circuit
Humidity5-95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Control MethodVector Control