Parameter Details
5
5.13 Y: Application Features
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference 429
Note:
• The drive response changes when the YF-23 [PI Aux Ctrl Output Level Select] setting changes.
–YF-23 = 0 [Direct Acting]:
When the PI Aux Feedback level is more than YF-25 [PI Aux Control Activation Level] for longer than this time, the drive will activate the
PI Auxiliary Control to control the output frequency.
–YF-23 = 1 [Inverse Acting]:
When the PI Aux Feedback level is less than YF-25 for longer than this time, the drive will activate PI Auxiliary Control to control the
output frequency.
• When you set this parameter to 0.0 PSI, PI Auxiliary Control is always enabled.
â–  YF-32: PI Aux Custom Unit Character 1
No.
(Hex.)
Name Description
Default
(Range)
YF-32
(3F6F)
PI Aux Custom Unit
Character 1
Sets the first character of the PI Aux custom unit display when YF-21 = 49 [PI Aux Ctrl Level Unit
Selection = Custom (YF-32~34)].
41
(20 - 7A)
Refer to Custom Units on page 213 for more information about available selections.
â–  YF-33: PI Aux Custom Unit Character 2
No.
(Hex.)
Name Description
Default
(Range)
YF-33
(3F70)
PI Aux Custom Unit
Character 2
Sets the second character of the PI Aux custom unit display when YF-21 = 49 [PI Aux Ctrl Level
Unit Selection = Custom (YF-32~34)].
41
(20 - 7A)
Refer to Custom Units on page 213 for more information about available selections.
â–  YF-34: PI Aux Custom Unit Character 3
No.
(Hex.)
Name Description
Default
(Range)
YF-34
(3F71)
PI Aux Custom Unit
Character 3
Sets the third character of the PI Aux custom unit display when YF-21 = 49 [PI Aux Ctrl Level Unit
Selection = Custom (YF-32~34)].
41
(20 - 7A)
Refer to Custom Units on page 213 for more information about available selections.
â–  YF-35: PI Aux Minimum Transducer Scale
No.
(Hex.)
Name Description
Default
(Range)
YF-35
(3F72)
PI Aux Minimum
Transducer Scale
Sets the minimum scale output of the pressure transducer that is connected to the terminal set for H3-
xx = 27 [MFAI Function Selection = PI Auxiliary Control Feedback].
0.0 PSI
(-999.9 - +999.9 PSI)
Note:
• To enable this parameter, set it to less than YF-02 [PI Aux Control Transducer Scale]. If you set it to more than YF-02, it will disable the PI
Auxiliary Feedback (set to 0).
• Parameters YF-21 [PI Aux Ctrl Level Unit Selection] and YF-22 [PI Aux Level Decimal Place Pos] set the unit and resolution.

Table of Contents

Other manuals for YASKAWA HV600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA HV600 and is the answer not in the manual?

YASKAWA HV600 Specifications

General IconGeneral
CategoryDC Drives
SeriesHV600
Overload Capacity150% for 60 seconds
Output Voltage0 - Input Voltage
EnclosureNEMA 1, NEMA 12
CommunicationEthernet/IP, Modbus, DeviceNet, Profibus
SafetySafe Torque Off (STO)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short Circuit
Humidity5-95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Control MethodVector Control