EasyManua.ls Logo

YASKAWA HV600

YASKAWA HV600
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
5
5.13 Y: Application Features
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference 429
Note:
The drive response changes when the YF-23 [PI Aux Ctrl Output Level Select] setting changes.
YF-23 = 0 [Direct Acting]:
When the PI Aux Feedback level is more than YF-25 [PI Aux Control Activation Level] for longer than this time, the drive will activate the
PI Auxiliary Control to control the output frequency.
YF-23 = 1 [Inverse Acting]:
When the PI Aux Feedback level is less than YF-25 for longer than this time, the drive will activate PI Auxiliary Control to control the
output frequency.
When you set this parameter to 0.0 PSI, PI Auxiliary Control is always enabled.
YF-32: PI Aux Custom Unit Character 1
No.
(Hex.)
Name Description
Default
(Range)
YF-32
(3F6F)
PI Aux Custom Unit
Character 1
Sets the first character of the PI Aux custom unit display when YF-21 = 49 [PI Aux Ctrl Level Unit
Selection = Custom (YF-3234)].
41
(20 - 7A)
Refer to Custom Units on page 213 for more information about available selections.
YF-33: PI Aux Custom Unit Character 2
No.
(Hex.)
Name Description
Default
(Range)
YF-33
(3F70)
PI Aux Custom Unit
Character 2
Sets the second character of the PI Aux custom unit display when YF-21 = 49 [PI Aux Ctrl Level
Unit Selection = Custom (YF-3234)].
41
(20 - 7A)
Refer to Custom Units on page 213 for more information about available selections.
YF-34: PI Aux Custom Unit Character 3
No.
(Hex.)
Name Description
Default
(Range)
YF-34
(3F71)
PI Aux Custom Unit
Character 3
Sets the third character of the PI Aux custom unit display when YF-21 = 49 [PI Aux Ctrl Level Unit
Selection = Custom (YF-3234)].
41
(20 - 7A)
Refer to Custom Units on page 213 for more information about available selections.
YF-35: PI Aux Minimum Transducer Scale
No.
(Hex.)
Name Description
Default
(Range)
YF-35
(3F72)
PI Aux Minimum
Transducer Scale
Sets the minimum scale output of the pressure transducer that is connected to the terminal set for H3-
xx = 27 [MFAI Function Selection = PI Auxiliary Control Feedback].
0.0 PSI
(-999.9 - +999.9 PSI)
Note:
To enable this parameter, set it to less than YF-02 [PI Aux Control Transducer Scale]. If you set it to more than YF-02, it will disable the PI
Auxiliary Feedback (set to 0).
Parameters YF-21 [PI Aux Ctrl Level Unit Selection] and YF-22 [PI Aux Level Decimal Place Pos] set the unit and resolution.

Table of Contents

Other manuals for YASKAWA HV600

Related product manuals