1.10 o: Operator Related Settings
236 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
o2: Operator Key Selections
These parameters determine the functions assigned to the operator keys.
o2-01: LO/RE (LOCAL/REMOTE) Key Function Selection
Parameter o2-01 determines whether the LO/RE key on the digital operator will be enabled
or not for switching between LOCAL and REMOTE.
Setting 0: Disabled
The LO/RE key is disabled.
Setting 1: Enabled
The LO/RE switches between LOCAL and REMOTE operation. Switching is possible
during stop only. When LOCAL is selected, the LED indicator on the LO/RE key will light
up.
NOTICE: When parameter b1-07 is set to 1 and the drive is switched from LOCAL to REMOTE while the
Run command at the REMOTE source is active, operation will start immediately. Refer to b1-07: LOCAL/
REMOTE Run Selection on page 45 for details and warnings.
o2-02: STOP Key Function Selection
Selects if the STOP key on the digital operator can be used to stop the operation when the
drive is controlled from a remote source (i.e., not from digital operator)
Setting 0: Disabled
The STOP key has no function when the drive is controlled by a source other than the digital
operator. The drive can only be stopped from the Run command source that has been
selected.
No. Name Setting Range Default
o1-11 User-Set Display Units Decimal Display 0 to 3
Determined by
o1-03
No. Name Setting Range Default
o2-01 LO/RE Key Function Selection 0 or 1 1
No. Name Setting Range Default
o2-02 STOP Key Function Selection 0 or 1 1