378 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
A.5 Defaults Determined by Drive Capacity (o2-04) and Normal/Heavy
A.5 Defaults Determined by Drive Capacity
(o2-04) and Normal/Heavy Duty (C6-01)
Table A.5 Single-Phase, 200 V Class Drives
Default Settings by Drive Capacity and ND/HD Settings
No. Description Unit Default Settings
Model VZA B0P1 B0P2 B0P4
C6-01 Normal/Heavy Duty Sel. HD ND HD ND HD ND
o2-04 Drive Model Selection Hex 30 31 32
E2-11
(E4-11,
T1-02)
Motor rated power kW 0.1 0.2 0.2 0.4 0.4 0.75
b3-06 Speed Search current 1 111111
b8-04 Energy saving coefficient 481.7 356.9 356.9 288.2 288.2 223.7
C6-02 Carrier frequency 474747
E2-01
(E4-01,
T1-04)
Motor rated current A 0.6 1.1 1.1 1.9 1.9 3.3
E2-02
(E4-02)
Motor rated slip Hz 2.5 2.6 2.6 2.9 2.9 2.5
E2-03
(E4-03)
Motor no-load current A 0.4 0.8 0.8 1.2 1.2 1.8
E2-05
(E4-05)
Motor line-to-line resistance 35.98 20.56 20.56 9.842 9.842 5.156
E2-06
(E4-06)
Motor leakage inductance % 21.6 20.1 20.1 18.2 18.2 13.8
E2-10
(E4-10)
Motor Iron Loss W 6 11 11 14 14 26
E5-01 Motor code hex FFFF FFFF FFFF FFFF 0002 0002
L2-02
Momentary power loss ride-
through time
s 0.1 0.1 0.1 0.1 0.1 0.1
L2-03
Mom. power loss Baseblock
time
s 0.2 0.2 0.2 0.2 0.2 0.3
L2-04
Momentary power loss
voltage recovery time
s 0.3 0.3 0.3 0.3 0.3 0.3
L2-05 UV detection voltage V dc 160 160 160 160 160 160
L3-24 Motor acceleration time s 0.178 0.178 0.178 0.178 0.178 0.142
L8-02 Overheat alarm level °C 115 115 115 115 110 110
L8-09 Ground fault selection 000000
L8-35 Installation method selection 000000
L8-38 Carrier freq. reduction sel. 111111
n1-03 Hunting Prev. Time Const. ms 10 10 10 10 10 10