A.5 Defaults Determined by Drive Capacity (o2-04) and Normal/Heavy
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual 379
Parameter List
A
No. Description Unit Default Settings
Model VZA B0P7 B1P1 B2P2 B4P0
C6-01 Normal/Heavy Duty HD HD ND HD ND HD
o2-04 Drive Model Selection Hex 33 34 35 37
E2-11
(E4-11,
T1-02)
Motor rated power kW 0.75 1.1 1.5 2.2 2.2 3.0 3.7
b3-06 Speed Search current 1 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-04 Energy saving coefficient 223.7 169.4 169.4 156.8 156.8 136.4 122.9
C6-02 Carrier frequency 473737 3
E2-01
(E4-01, T1-
04)
Motor rated current A 3.3 6.2 6.2 8.5 8.5 11.4 14.0
E2-02
(E4-02)
Motor rated slip Hz 2.5 2.6 2.6 2.9 2.9 2.7 2.73
E2-03
(E4-03)
Motor no-load current A 1.8 2.8 2.8 3 3 3.7 4.5
E2-05
(E4-05)
Motor line-to-line resistance 5.156 1.997 1.997 1.601 1.601 1.034 0.771
E2-06
(E4-06)
Motor leakage inductance % 13.8 18.5 18.5 18.4 18.4 19 19.6
E2-10
(E4-10)
Motor Iron Loss W265353777791 112
E5-01 Motor Code hex 0003 0003 0005 0005 0006 0006 0008
L2-02
Momentary power loss ride-
through time
s 0.2 0.2 0.3 0.3 0.5 0.5 1.0
L2-03
Momentary power loss
Baseblock time
s 0.3 0.4 0.4 0.5 0.5 0.5 0.6
L2-04
Momentary power loss
voltage recovery time
s 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L2-05 UV detection voltage V dc 160 160 160 160 160 160 160
L3-24 Motor acceleration time s 0.142 0.142 0.166 0.145 0.145 0.145 0.154
L8-02 Overheat alarm level °C 105 105 100 100 95 95 100
L8-09 Ground fault selection 000000 0
L8-35 Installation method selection 000000 0
L8-38
Carrier frequency reduction
selection
111111 1
n1-03
Hunting Prevention Time
Constant
ms 10 10 10 10 10 10 10

Table of Contents

Related product manuals