A.2 Parameter Table
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual 327
Parameter List
A
◆ H Parameters: Multi-Function Terminals
H parameters assign functions to the multi-function input and output terminals.
F7-09 Gateway Address 1
Combining these parameters like F7-09.F7-
10.F7-11.F7-12 sets the Ethernet Gateway
Address.Example: (192.168.1.1).
0 to 255
192
<60>
AAA 3ED 136
F7-10 Gateway Address 2 0 to 255
168
<60>
AAA 3EE 136
F7-11 Gateway Address 3 0 to 255
1
<60>
AAA 3EF 136
F7-12 Gateway Address 4 0 to 255
1
<60>
AAA 3F0 136
F7-13
Address Mode at
Startup
Selects how the Ethernet IP address is set.
0:User defined
1:BOOTP
2:DHCP
0 to 2 0 A A A 3F1 137
F7-14
<59>
Duplex Mode
Selection
0:Auto Negotiate
1:Half Duplex forced
2:Full Duplex forced
0 to 2 0 A A A 3F2 137
F7-15
<59>
Communication Speed
Selection
0:Auto Negotiate
10:10 Mbps speed setting
100:100Mbps Speed Setting
0, 10,
100
0 AAA 3F3 137
F7-16
<59>
Communication Loss
Timeout
Sets the timeout value for communication loss
detection.
0 to 300 0 A A A 3F4 137
F7-17
<59>
Ethernet Speed
Scaling Factor
Sets the scaling factor for the speed monitor in
Ethernet Class ID 2AH Object.
-15 to
15
0 AAA 3F5 138
F7-18
<59>
Ethernet Current
Scaling Factor
Sets the scaling factor for the output current
monitor in Ethernet Class ID 2AH Object.
-15 to
15
0 AAA 3F6 138
F7-19
<59>
Ethernet Torque
Scaling Factor
Sets the scaling factor for the torque monitor in
Ethernet Class ID 2AH Object.
-15 to
15
0 AAA 3F7 138
F7-20
<59>
Ethernet Power
Scaling Factor
Sets the scaling factor for the power monitor in
Ethernet Class ID 2AH Object.
-15 to
15
0 AAA 3F8 138
F7-21
<59>
Ethernet Voltage
Scaling Factor
Sets the scaling factor for the voltage monitor in
Ethernet Class ID 2AH Object.
-15 to
15
0 AAA 3F9 138
F7-22
<59>
Ethernet Time Scaling
Sets the scaling factor for the time monitor in
Ethernet Class ID 2AH Object.
-15 to
15
0 AAA 3FA 138
<58> Valid from drive software 1011 and later. Parameters F6-50 to F6-54 had parameter numbers F6-20 to F6-24 in
older software.
<59> Available in drive software 1011 and later.
<60> Default Setting valid for drive software 1011 and later.